Specifically for the substation when the power transformer on-site maintenance to oil storage or oil filtration.
3e-GFT2
tank
is designed for
power transformer
substation
installation and maintenance
and design.
It c
an
be stored
transformer oil
temporarily
and
oil
vacuum filtration operation
.
It
can
greatly reduce the
use of
heavy
steel tank for
transportation costs
and maintenance costs.
The
3e-GFT2
tank
can be folded
, light weight,
tank
insulation, and
also
greatly reduced the maintenance
and operation of
the labor intensity
and
personal safety.
Especially in the
underground substation
operation,
to better reflect
its advantages
.
The tank is made by material of reinforced fabric with TPU(Thermoplastic Polyurethane) coated.
It
has great
tensile strength.
All
through
high frequency welding
seam.
The outer surface of
the material
with anti-
UV
function,
in bad
weather conditions
have a long
life.
Specialized
coating
the inner surface of
the material
resistant to
transformer
oil
coating
, thus ensuring
long-term
immersion
in
transformer oil
, the material
does not pollute the
oil
.
3e-GFT2
tank
after
the oil
tank
was
full of
pillow
shape.
Inlet valve
,
a valve
installed in
the top and
bottom of
the tank
and form a
diagonal
structure.
This
structure is easy to
clean and
the
residual
emission
.
Features:
1,Save oil purification time: The Inlet and Outlet valves size:DN50 are located at the opposite ends of the tanks diagonal. During oil purification, there are usually some blind spots at the corners of the oil tank. The diagonal structure will help to reduce the oil purification time.
2, Easy and convenient to discharge oil: Since the outlet is located at the side of the tank, it is easy to discharge the oil.
3, Auto Air Exhaustion: there is an auto-air-exhaustion vent (3kPa threshold)located in the middle of the tank on the top, so that the workers do not need to manually vent out the air in the tank.
4, The unique coin drain port(option)at the bottom of the tank: if necessary, your can use this drain port to let out the sewage oil(suggestion it will be installed in the more than 40000 liters capacity tanks).
5, Light in weight and small in size.
Meterial Data:
Structures & Properties
Test Methods
Base Fabric
100% PES 2000 dtex
Inner Coating
Polyester Polyurethane Polymer with DP18
ASTM D3487
Outer Layer Coating
Polyester Polyurethane Polymer with UV resistance
Material Weight
1100 g/m2
DIN EN ISO 2286-2
Tensile Strength
5000 N/5cm (Warp)
ASTM D751-A
4500 N/5cm (Weft)
Tear Strength
600 N (Warp)
ASMD D751-B
500 N (Weft)
Temperature Resistance
-30 to +80
ASMD D2136,D1204
Adhesion
400 N/5cm
ASMD D751
Color
Yellow
Crack-Resistance
100,000
DIN 53359A
Specification:
Model #
Capacity
(Liter)
Empty Size
(m²)
Full High
(m)
Net Weight
(kg)
GFT-2
2,000
3.4 x 1.7
0.40
GFT2-5
5,000
3.7 x 3.3
0.65
40
GFT2-10
10,000
5.0 x 3.7
0.85
59
GFT2-15
15,000
6.4 x 3.7
0.85
73
GFT2-20
20,000
5.6 x 4.6
0.90
81
GFT2-30
30,000
6.9 x 5.6
1.00
121
GFT2-50
50,000
7.7 x 7.6
1.10
180
GFT2-60
60,000
9.2 x 7.6
1.10
215
Note: We also customize products according to customers requirements.